The Fridge Defend by ARP helps keep your Dometic reliable while increasing safety, efficiency & reliability. This is the install page for the 3, 4, & 5 cubic foot series of Dometic RV fridge.
REQUIRED TO DOWNLOAD INSTALLATION INSTRUCTIONS - WEB PAGES ARE SUPPLEMENTAL - EACH VERSION OF CONTROL HAS INTRICACIES REQUIRING THE WRITTEN INSTRUCTIONS.
Instructions: Subjects are listed on left. Click the link to the right to go directly to the subject matter on this page.
The Dometic 3, 4, & 5 cubic foot RV refrigerators are very efficient as long as the cooling unit boiler is not allowed to overheat. The problem with these refrigerators is that they are mostly found in slide-in campers, class-b, and other everyday driver type RV conversions. As a result there is a high failure rate due to off-level use and other factors associated with everyday driving that destroys the cooling unit.
Please click here to see how the ARP Control can make your Dometic safer, more reliable, & efficient.This image shows a typical installation for the Fridge Defend by ARP on a Dometic 3, 4, or 5 cubic foot fridge. This drawing shows wiring for either the 2-way or the 3-way installations. The only difference between the two types of fridge models is the 2-way fridge will not have relay #6.
Please click here for the details of wiring the 2-way models without the boiler thermal switch.
For the 3-way models that have relay #6. please click here for further details.
Click here if your fridge has a boiler thermal switch that is wired in line with the power supply.
Click here for temperature sensor install video.
Please click here for the ARP blower fan and temperature sensor installation.
Please see the full ARP User Manual and Installation Guide for more information needed before using your ARPrv Control.
Please note that all of the following specifications are believed to be accurate. If any errors are found, please bring them to our attention as soon as possible. For critical specification please contact Dometic as they make changes to their specifications without notice.
Parameter | Value |
---|---|
Fridge Defend Boiler Temperature | 185-195 degC |
Fan Control Absorber Coil Temperature | 120-135 degF |
Off-Level Operating Limit | Click Here |
Minimum DC Power Supply | 9.6 VDC |
Maximum DC Power Supply | 22 VDC |
Maximum AC on 12VDC Supply Line | 6 VAC |
Board 12VDC Fuse | 3 A |
Board AC Fuse | 5 A |
VAC Operating Range | 100-132 VAC |
DC Heater Power Rating | 175 W |
DC Heater Current | 15 A |
DC Heater Resistance per Heater (cold) | 0.8 Ohms |
DC Heater Fuse | 30 A |
AC Heater Power Rating | 175 W |
AC Heater Current | 1.5 A |
Heater Resistance per Heater (cold) | 80 Ohm |
Gas Pressure | 10.5-11.5 Inch-H2O |
Gas Jet | #43 |
Gas Thermocouple | --- |
Electrode to Burner Gap | 3/16 inch |
Thermistor @ 33degF to 35degF | 8k-10k Ohm |
Parameter | Value |
---|---|
Fridge Defend Boiler Temperature | 185-195 degC |
Fan Control Absorber Coil Temperature | 120-135 degF |
Off-Level Operating Limit | Click Here |
Minimum DC Power Supply | 9.6 VDC |
Maximum DC Power Supply | 22 VDC |
Maximum AC on 12VDC Supply Line | 6 VAC |
Board 12VDC Fuse | 3 A |
Board AC Fuse | 5 A |
VAC Operating Range | 100-132 VAC |
DC Heater Power Rating | 150 W |
DC Heater Current | 12.5 A |
DC Heater Resistance per Heater (cold) | 0.96 Ohms |
DC Heater Fuse | 30 A |
AC Heater Power Rating | 175 W |
AC Heater Current | 1.5 A |
Heater Resistance per Heater (cold) | 80 Ohm |
Gas Pressure | 10.5-11.5 Inch-H2O |
Gas Jet | #39 |
Gas Thermocouple | --- |
Electrode to Burner Gap | 3/16 inch |
Thermistor @ 33degF to 35degF | 8k-10k Ohm |
If you cannot find what you need please use the Contact Us form from the top menu.