Norcold N4104 | N4141 | | N4150 | N4151

This page shows how to improve the efficiency and safety of your Norcold N4104, N4141, or N4150. In addition we provide Service Manual specifications.

REQUIRED TO DOWNLOAD INSTALLATION INSTRUCTIONS - WEB PAGES ARE SUPPLEMENTAL - EACH VERSION OF CONTROL HAS INTRICACIES REQUIRING THE WRITTEN INSTRUCTIONS.

Table of Contents

Instructions: Subjects are listed on left. Click the link to the right to go directly to the subject matter on this page.


Winnebago Norcold N3150

Overview of N4104, N4141, N4150, & N4151

The first photo is of a Winnebago with the Norcold N4151. The N4150 replaces the N3150. The main difference between the N31xx and N41xx is that the N41xx as a touchscreen display.

Following we will discuss the features of the Norcold refrigerator. Also shown is how to install the ARP boiler sensor and wiring.

Click here for post on Sprinter Forum "I installed a newer version 3.1 ARP on my 2016 Winnebago View24J."

For further information on recommended fan install: ARP + Fan Control


N3104 N3150

N41xx Failure

The all if the N41xx series fridge are controlled by electrical controls.

These fridges are prone to failure due to the fact that they are mostly in small RVs that can be used in day to day driving. As a result, these fridges are left running and parked off-level. The fridge will overheat and be damaged within 15 minuets when parked 3 degrees off level. For this reason, the ARP Control is a must for vehicles that are used often in a situation where damage may occur.

Please click here to see video of Norcold N3150 being protected by the Fridge Defend.

Norcold N4104 N4141 N4150 N4151 Wiring

Wiring Norcold N4104, N4141, N4150, or N4151

Download PDF printable drawing by clicking here.

This drawing shows the 6-connector plug that connects the Norcold fridge to the RV. Upper right is wires going to Norcold fridge control, lower left are the wires going to the RV. Each RV manufacture uses different wire colors. Also, in the lower right corner is the identification of the terminals within the plug with the wire description and color where the terminal is. In order to wire the ARP Control, the lead marked LC+ (Low Current Positive) needs to be identified. The ARP will be spliced into this wire. The ARP red wire will connect to the battery side of the LC+ wire and the ARP yellow wire will connect into the end of the splice going to the Norcold fridge.

We recommend using a male and female insulated spade connector for the splice ends. This makes it easy to reconnect the splice if one wants to restore factory settings or troubleshoot the fridge.


Pictorial N4104 N4141 N4150

The wiring diagram to the left has been included to help if your wiring sticker has come off your fridge. This gives the entire fridge wiring diagram.


N3104 N3150 Over Heat Protection

Install ARP Boiler Sensor

The ARP boiler temperature sensor is quite easy to install on the N41xx series. Some fridges may need to be removed for the install, some folks have chosen to just install the fan control until there fridge needs to be removed for service for the boiler sensor install.

This photo shows the proper location for the ARP sensor. Staring at the top orange arrow, the ARP sensor (purple arrow) shall be mounted below the top absorber coil (orange arrow). The ARP boiler sensor will be mounted on the boiler tube, the boiler tube is behind the flue tube (red arrow). The ARP sensor should be at least 1 inch above the electric heaters (blue arrow). Download the full installation instructions for further details.


Norcold LP Gas Troubleshooting

If your fridge is not preforming properly on LP Gas, but works fine on shore power, the issue may be a plugged filter in the refrigerators solenoid operated valve (SOV).
Click here for LP filter cleaning instructions.
Click here for LP filter cleaning video.


Norcold 12V Heater Troubleshooting

If your fridge is not preforming properly with 12V heater, but works fine on shore power, the issue may be an overheated trace on your control board. Click here for fix of common control board problem that results in 12V heater not working.


Fault / Error Codes N41xx

# of LIGHTS MEANING POSSIBLE SOLUTION
1 Controller senses LP flame, but LP mode not selected. Remove cover of gas burner check if flame present; gas valve stuck open; igniter wiring issues. See next error for more troubleshooting on this issue.
2 LP Igniter Issue Remove LP burner cover, check electrode gap, clean burner, check wiring and ground for LP igniter.
Click here for igniter adjustment.
3 Flame did not ignite. The flame attempts to ignite for 30 seconds. Empty LP tank, high wind, low LP pressure, igniter adjustment, can result in this error. Reset fridge by turning on/off, if will not solve issue see this link:
Click here for filter cleaning and LP pressure adjustment.
Manual shutoff valve is closed on LP solenoid.
4 12V heater is set to turn on, but does not. Click here for fix of common control board problem that results in 12V heater not working.
5 12V heater is off, should be on. Use link in above error code 3, test DC heater resistance using value in table below. Tap on relay seen in above link, may be stuck shut? Try cycling fridge on/off.
6 12VDC voltage out of range. Proper DC voltage range is between 10 to 15 volts checked at terminals LC+ & LC- seen in wiring drawing above.
7 Fridge set to Manual DC Mode and there is "no engine running" displayed. Check for 12VDC at HC+ and HC- leads seen in drawing above. Check the D+ signal wire for proper signal. 
Click here for fix of common control board problem that results in 12V heater not working.
8 120VAC heating element failure. Check shore power, check both heating elements for proper resistance using table below.
Click here to check heater resistance.
Click here to check heater shore power and GFI safety
9 Shore power heater is on, should be off. The control board relay is stuck closed. Try tapping on relay to free. Try cycling the fridge on/off a few times.
10 Shore power 120VAC out of range. The proper shore power range is from 108 to 132VAC.
11 Fridge is in Auto Mode, but fridge cannot find an energy source. Try cycling fridge on/off. Change out of the Auto Mode. Check LP, 12VDC, and 120VAC as described above.
12 Communications error. The display board on front of fridge is not communicating (COM) with the back control board:
Click here, the first photo shows the "COM", it is the brown arrow to the right, check this connection.
13 Thermistor failure, control is in backup operating mode. The control unit is not getting an input it needs to run.
Fridge thermistor has failed.
Click here to check thermistor.
Check all wiring connections, power down the fridge and then power up.
18 Fridge not able to start. Preform all checks described above, this is a very ambiguous error we are aware. Start with the 12VDC supply to fridge to see if in range while attempting to start fridge.

Norcold N41xx Specification Table

Please note that all of the following specifications are believed to be accurate. If any errors are found, please bring them to our attention as soon as possible. For critical specification please contact Norcold as they make changes to their specifications without notice.

Item Value Units
ARP Control Boiler Temperature See Note 1 Below
N3104 Volume 3.7 cu. ft
N3150 5.3 cu. ft
Off-Level Operating Limit See Note 2 Below
Temp Setting Range 1 - 5 5 = Coldest | See Note 3 Below

Fuses

Item Value Units
Board 12V Fuse 20 Amp
120VAC See Note 4 Below Amp

DC Power

Item Value Units
Automatic Ignition 0.5 Amp
Flapper Heater 0.3 Amp
DC Heater N3104 15.8 Amp
DC Heater N3150 17.1 Amp
Fan 0.24 Amp
Total Amp Draw N3150 18.14 Amp

AC Power

Item Value Units
Operating Range 108 - 132 VAC
AC Heater N3104 1.8/66 Amps/Ohms
AC Heater N3150 2.5/48
Measurement Conditions 120 VAC

LP Gas

Item Value Units
Gas Pressure 10.5 - 11.5 inch w.c.
Heat Input not given BTU/hour
Gas Jet not given
Gas Jet (new style) not given
Electrode to Burner Gap 1/8" to 3/16" inch

NOTES

Note 1: 185-195°C - 365-383°F

Note 2: Dependent on ambient and ARP boiler temp.

Note 3: Thermistor Values

Note 4: 5 Amp type AGC fast acting.